BK PRECISION 8510 CALIBRATION and BK PRECISION 8510 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 8510 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Electronic Load?
Shop for Comparable Products on our
 used Electronic Load page

 
   BK PRECISION 8510   Description / Specification:    
BK PRECISION 8510 120A 600W Single Input Electronic Load

The BK Precision 8510 600 W Programmable DC Electronic Load can be used for testing and evaluating a variety of DC power sources. It's wide operating ranges of up to 120 V and 120 A, flexible operating modes and excellent measurement accuracy make the 8510 well suited for characterizing DC Power supplies, DC-DC Converters, batteries, fuel cells and solar cells. The loads can operate in CC, CV, CR or CP mode while voltage/current or resistance/power values are measured and displayed in real time. Load terminals are isolated and floating. Extensive protection, including over temperature, over power, over voltage, over current and reverse polarity will help protect your valuable prototype. The DC loads are easy to use. All parameters can be set quickly and precisely from the front panel, or programmed via RS232 (included) or USB (optional) interfaces. Specifications. Input rating Voltage: 0 to 120 V. Input rating Current: 0 to 120 A. CV Mode Regulation Range: 0.1 to 18 V (Accuracy ±(0.05%+0.02% FS), Resolution 1 mV), 0.1 V to Vmax (Accuracy ±(0.05%+0.025% FS), Resolution 10 mV). CC Mode Regulation Range: 0 to 12 A (Accuracy ±(0.1%+0.1% FS), Resolution 1 mA), 0 to max Current (Accuracy ±(0.2%+0.15% FS), Resolution 10 mA). Current Measurement Range: 0 to 12 A (Accuracy ±(0.1%+0.1% FS), Resolution 1 mA), 0 to max Current (Accuracy ±(0.2%+0.15% FS), Resolution 10 mA). Voltage Measurement Range: 0 to 18 V (Accuracy ±(0.02%+0.025% FS), Resolution 1 mV), 0 V to Vmax (Accuracy ±(0.02%+0.025% FS), Resolution 10 mV).



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 8510. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your BK PRECISION 8510 CALIBRATION and/or BK PRECISION 8510 120A 600W Single Input Electronic Load REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: